A full polishing range.
From cutting and one-step correction to final finishing.
A dilution instruction expressed by mass is not automatically equivalent to the same numerical ratio by volume. Preserve the basis stated by the manufacturer and use the appropriate measuring method for the product.
Updated · NANOLAB Knowledge
Mass and volume describe different quantities. Converting between them requires relevant density information, not an assumption that every cleaner behaves like water. A workshop should make the instruction basis visible on its preparation record so that operators do not alternate methods while believing they are preparing the same dilution.
Illustrative example: one operator weighs concentrate while another measures the same number of millilitres. If the product's density is not one gram per millilitre, those additions are not identical. The useful correction is a consistent approved method, not an undocumented adjustment made after comparing cleaning results.
Do not change concentration to compensate for an uncertain calculation. This guide does not provide a dilution ratio for any NANOLAB cleaner. Follow the exact product instructions, and keep concentrate identity, water quantity and preparation date available where the workshop's process requires them.
Ask NANOLAB about the exact product and intended use. Use the current product documentation for formulation-specific instructions.